Visual Field Analyser Buying Checklist for Australian Eye Clinics

visual field analyser

A visual field analyser can stay in service for years. The right unit needs to fit the patients you see, the tests you run, the space you have, staff workflow and the data you need to keep.

This visual field analyser buying checklist gives owner optometrists, ophthalmologists, and procurement teams a practical way to compare automated perimeters and portable systems before a demo or quote. The goal is to match the instrument to clinical use, workflow and long-term support rather than price or form factor alone.

Key Highlights

  • Start with patient mix and required test patterns.
  • Compare repeatability, fixation monitoring and report quality during a live demo.
  • Decide whether a fixed automated perimeter or portable visual field analyser fits room use and patient access.
  • Check how results move into record systems and how baseline data is stored.
  • Price the full ownership cycle: hardware, modules, training, service, software and warranty.

Which Tests and Patient Groups Must the Instrument Support?

Perimeter choice starts with the work the clinic needs to perform. A long feature list has little value if key test patterns, progression tools or access features are missing.

Build a Clinical-Use List Before Comparing Models

Patient group or task Capability to verify Demo question
Glaucoma suspects and follow-up
24-2, 24-2C, 10-2, 30-2, threshold strategies and progression review
Can staff run the clinic’s usual protocol and compare prior fields?
Early or paracentral glaucoma
Dense central testing and clear central reports
How are central defects displayed and trended?
Neuro-ophthalmic assessment
Wider field patterns, neuro protocols and kinetic options where needed
Which protocols are standard or optional?
Ptosis and functional field work
Ptosis patterns and Estermann-style testing where relevant
Can the clinic review sample reports before purchase?
Older patients or limited mobility
Clear instructions, pause options and flexible positioning
Can the unit work with the clinic’s common chair and room setup?

Clinics building a shortlist can review BOC Instruments’ range of Visual Field Analysers for Sale before a demonstration. Comparing available systems against the clinic’s most common patient groups can help narrow the options before discussing technical specifications.

A 2026 study on visual field progression adds a workflow point. Staged schedules starting with two tests every three or six months detected 50% of progressors in 21–36 months, compared with 60–96 months for fixed annual review models. This is not a rule for every patient. It shows why glaucoma clinics may place high value on repeatability, throughput and progression analysis.

Before comparing quotes, write down the five most common visual field jobs in the clinic. Use that list as the first filter.

Bowl Versus Portable Workflow and Room Needs

Form factor can affect patient positioning, technician time, room scheduling, hygiene and where testing can take place.

BOC Instruments currently lists the FREY AP-600/AP-600L automated perimeters and the VF2000 NEO portable visual field analyser. The AP-600 family includes eye-position monitoring, head sensors and patient audio guidance. The VF2000 NEO is portable, needs no darkened room and includes active eye tracking with threshold, neuro, kinetic, ptosis and Estermann testing.

Compare the Workflow, Not Just the Footprint

Buying point Fixed or bowl-style system Portable or headset-based system
Room use
Stable testing station
Can support testing across rooms or sites
Patient position
Check chin, forehead, chair and wheelchair access
Check headset fit, comfort and response method
Ambient light
Confirm room-light requirements
Some systems can work without a dark room; verify the model
Staff workflow
Check setup, alignment and monitoring steps
Check eye tracking and when staff input is needed
Repeat testing
Check how quickly the next test can start and save
Check cleaning, charging and result transfer

Portable perimetry has a growing evidence base, but buyers should keep device-level validation in view. A 2025 systematic review included 14 studies comparing 10 virtual-reality perimeter systems with standard automated perimetry. Results were promising, yet the authors called for more data on test–retest repeatability.

For a portable visual field analyser in clinic use, portability is only one part of the decision. Report quality, repeatability, patient fit and data continuity still need to meet clinical requirements.

Reliability, Fixation and Reporting Questions for a Demo

A visual field report can look complete and still need clinical review. Reliability indices, fixation behaviour and test conditions matter, yet a single flag should not be treated as a simple pass-or-fail rule.

A 2022 UNSW study analysed 2,320 SITA-Faster visual field results from 1,160 eyes. Common reliability cut-offs could exclude fields that remained clinically useful. Above a 12% false-positive rate, mean deviation changed by an average of 0.09 dB for each 1% rise. The study supports reading reliability measures in context rather than relying on one threshold alone.

Ask the Supplier to Show These Points Live

  • Fixation monitoring: Can the operator see gaze or eye position during testing?
  • Test control: What happens after a blink, fixation loss or patient pause?
  • Reliability indices: Are false positives, false negatives and fixation data easy to review?
  • Normative data: What age range and reference population support the probability maps?
  • Progression tools: Which indices are trended, and can old data be imported?
  • Report layout: Are deviation maps, global indices and defect patterns easy to interpret?


For automated perimeter selection, request sample reports before the quote stage. Run the same patient twice during a demo where practical. This gives the team a direct view of setup, repeatability and report consistency.

Use several representative cases: a new glaucoma suspect, a stable follow-up, an advanced defect, an older patient who tires during testing and a patient with positioning needs.

Data Export, Training and Service Questions

Perimetry creates long-term clinical data. A new instrument should make those results easy to find, compare and transfer years later.

Ask for a Live Data-Flow Demonstration

Have the supplier show the path from patient selection to saved result. Check:

  • PDF, DICOM or other structured export formats
  • worklist or patient-demographic transfer
  • links with practice, imaging or electronic record systems
  • legacy-field import or side-by-side review
  • backup, restore and user-access processes
  • software update, licence and multi-site rules


Equipment support should form part of the purchase assessment rather than being reviewed after installation. BOC Instruments provides Ophthalmic Equipment Repair, installation, training, system integration, maintenance and relocation support for ophthalmic practices.

That service layer matters for a device used in ongoing disease monitoring. Purchase price is easy to compare. Downtime, staff retraining, software issues and lost access to historical data are harder to price after installation.

Training should cover test selection, patient positioning, reliability review, cleaning, daily checks, report use, data export and common error messages. Multi-site groups can ask whether training can be repeated for new staff or delivered at more than one location.

Questions to Ask Before Requesting a Quote

Send the same checklist to each supplier so the comparison stays fair.

Question Why it matters
Which test patterns and strategies are included?
Some functions may sit in optional modules or licences.
Which progression tools are included?
Glaucoma follow-up may depend on trend or event analysis.
What is the full purchase cost?
Hardware may exclude software, freight, installation or training.
Are there recurring software or licence fees?
Annual costs affect the ownership budget.
What warranty and service support are included?
Coverage and response times affect downtime planning.
Is loan equipment available?
A loan unit may reduce disruption during repairs.
Can existing field data be migrated?
Baseline continuity matters for follow-up.
What export formats are supported?
Data access affects integration and future system changes.
What training is included?
Staff competency affects flow and test quality.

Clinics reviewing several diagnostic equipment purchases at the same time may find the OCT Machine Buying Guide useful for applying similar procurement principles to OCT technology, including workflow, clinical requirements, software and support.

Ask the quote to separate capital cost, optional modules, recurring fees, service plans and training. This gives procurement teams a clear cost comparison across three, five or more years.

Connect With BOC Instruments Today!

The best perimeter is the one that fits the clinic’s patient mix, produces reports clinicians can trust, works with current data systems and has a clear support path after installation.

BOC Instruments supplies visual field analyser options including the FREY AP-600/AP-600L and VF2000 NEO, with product advice, installation, training and technical service for Australian eye-care practices.

If your clinic is reviewing perimetry, bring BOC Instruments a short list of patient groups, required tests, room constraints, current software and service expectations. Ask the team to demonstrate the clinical workflow, report output and support process before requesting a final quote.

Use this visual field analyser buying checklist during the discussion so each option is judged against the same clinical and operational needs.

Frequently Asked Questions

A fixed or bowl-style unit gives the clinic a stable testing station. A portable system can reduce dependence on one room. The better fit depends on patient mix, test requirements, repeatability, report format and staff workflow.

Many glaucoma services use 24-2 or 24-2C testing, with 10-2 testing for selected central or paracentral questions. Confirm that the instrument supports the clinic’s current protocol and progression workflow.

Eye tracking can help monitor fixation and support test control on some devices. It does not replace clinical review of the field, reliability indices, defect pattern and patient behaviour.

Ask about PDF, DICOM, structured data export, worklist functions, backups, legacy-data import and access to records after a software or equipment change.

Use representative patients and normal clinic protocols. Compare setup time, comfort, fixation monitoring, repeatability, report reading, data transfer, staff steps, training and service support.